geoscience.net logo
+ Resolve Article
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter

+ Translate
+ Subscribe to Site Feed
GeoScience Most Shared ContentMost Shared Content

Environmental endotoxin measurement the kinetic limulus assay with resistant line estimation


, : Environmental endotoxin measurement the kinetic limulus assay with resistant line estimation. Environmental Research 57(2): 212-230

A Limulus assay method was specifically designed for environmental endotoxin aerosols. Application of new statistical and sample preparation methods strengthened the validity and precision of the Limulus test. Statistically, the Kinetic Limulus Assay with Resistant-parallel-line Estimation (KLARE) differed from conventional analytic methods (as used in chromogenic assays and other kinetic methods) by routinely using a dilution series of the unknown sample as well as the standard to compute potency and an estimate of variance for each sample. Analysis of dose-response slopes for the standard and unknowns detected inhibition and enhancement effects.sbd.without multiple assay. Concentration-dependent interference and a more complex, concentration-independent interference with the Limulus assay were detected. Resistant regression and a standardized data analysis corrected for concentration-dependent interference. Sample preparation in a buffer eliminated concentration-independent interference and, thus, improved both the validity and the precision of potency measurements. The utility of a sample buffer and of parallel-line analysis, with both turbidimetric and chromogenic lysates, was demonstrated by assay of three control standard LPS and reference LPS (EC5). The limit of detection for endotoxin was < 1 pg/ml in buffer. samples containing .gtoreq. 10 pg/ml were measured with a coefficient of variation of approximately 6% in a single assay. Reproducibility of potency estimates for four samples over 3 days was compared on the basis of standard errors of the mean. The conventional method gave on average a CV of 65% while the resistant-parallel-line method gave, on average, a CV of 6%. Also, the conventional method failed to detect interference and, thus, included data from invalid assays. Conventional analysis of environmental aerosol samples was highly sensitive to the choice of dilution factor causing as much as 1000% variation in the result. By contrast, KLARE results changed by at most 30% with similar changes in initial dilution because KLARE was able to detect, and correct for, the influence of interferant compounds.

US$29.90


Other references

Ilyinskaya, E.; Oppenheimer, C., 2009: Changes in aerosol chemistry in the plume of Kilauea Volcano caused by the 2008 summit eruption. Eos, Transactions, American Geophysical Union 90.22, SUPPL

Gould, D.H., 1977: Mesotheliomas of the tunica vaginalis propria and peritoneum in Fischer rats. Nine mesotheliomas were found in a group of 384 mature, male, Fischer-derived rats maintained on various experimental diets in long-term feeding studies. The tumors apparently were unrelated to any of the test materials. They ranged from solid, ra...

McGuinness, J.B., 1974: Displacement cardiography; a new technique for study of cardiac movement. Nursing Times 70(29): 1111-1112

S.A.A.khamisi; H.A.A.delrahman; M.A.med; M.F.A.G.osen, 2011: Assessment of reclaimed water irrigation on growth, yield, and water-use efficiency of forage crops. Field experiments were conducted to determine the effect of water quality (reclaimed and fresh water), water quantity, and their interactions on the growth, yield, and water use efficiency of forage maize during two winter seasons in the Arabian G...

Petrov A.I.; Sukhorukov B.I., 1977: Use of spin labels for investigating the association of adenosine amp adp and atp in aqueous solutions. Biophysics (English Translation of Biofizika) 22(5): 957-959

Houghton, J.T., 1977: Calibration of satellite radiation instruments. In 1973 COSPAR and the Radiation Commission set up an ad hoc committee to consider problems of calibration and intercomparison of radiation measuring instruments mounted on rockets or satellites. This committee organized the Grenoble symposium in...

Keenan, W.F., 1981: Pseudohypertension mimicking a hypertensive emergency. JAMA 246(10): 1088-1088

Bremmer, F.; Duhamel, J.R.; Ben Hamed, S.; Graf, W., 1996: Non-retinocentric coding of visual space in the macaque ventral intraparietal area. Society for Neuroscience Abstracts 22(1-3): 1692

Meyboom-de Jong, B., 2014: The future of geriatric care: The National Geriatric Care Program continued. Tijdschrift Voor Gerontologie en Geriatrie 45(2): 67-68

Ladouceur, M.; Latremouille, C.; Iserin, L., 2008: A giant atrial thrombosis in a patient with fontan circulation. We described a case of a quasi obstructive thrombus in the right atrium in a patient with a Fontan palliation. Different medical imaging techniques helped us for diagnosis and management strategy. We discussed the therapeutic choice between thromb...