geoscience.net logo
+ Resolve Article
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter

+ Translate
+ Subscribe to Site Feed
GeoScience Most Shared ContentMost Shared Content

Biomechanical analysis of a novel locking plate with smooth pegs versus a conventional locking plate with threaded screws for proximal humerus fractures


, : Biomechanical analysis of a novel locking plate with smooth pegs versus a conventional locking plate with threaded screws for proximal humerus fractures. Journal of Shoulder and Elbow Surgery 22(4): 445-450

Repair of proximal humeral fractures with locking plates has greatly improved outcomes. However, an alarming rate of complications including screw cutout and impingement under the acromion has recently been reported. A novel locking plate with smooth pegs was developed to reduce these risks. The purpose of this study was to compare these 2 fixation methods with a cadaveric biomechanical study. Fourteen pairs of cadaveric proximal humeri (mean age, 77 years) were harvested, and bone density was measured. Osteosynthesis was performed on each pair using either a locking plate with threaded screws (TS group) or smooth pegs (SP group) on the contralateral side. Seven pairs of humeri were tested for cyclic bending, and 7 pairs for cyclic torsional evaluation: TS bending, SP bending, TS torsion, and SP torsion. The bending protocol consisted of cyclically loading to a maximum of 7.5 Nm bending moment for 1, cycles. The torsion protocol consisted of 2 Nm of axial torque for 1, cycles. Surgical neck fractures were simulated by excising a 1-mm wedge of bone. No implant failure or screw cutout was observed in any of the groups tested. Under bending loads, mean displacement of the distal fragment was significantly less for the SP group than that for the TS group over 5, cycles. In torsion tests, no significant differences were observed between the 2 fixation methods. The SP group demonstrated superior biomechanical characteristics to the TS group in regards to cyclic bending.

US$19.90

PMID: 22743070

DOI: 10.1016/j.jse.2012.04.005


Other references

Park, E.; Weilenmann, D.; Bloch, K.; Kueffner, J.; Bornzin, G.; Candinas, R.; Levine, P.A., 1998: Activity-controlled circadian base rate. The current pacing rates are clustered around a fixed base rate since pacemaker patients are usually sedentary, resting, or sleeping most of the time. This fixed base rate is either too low for daytime hemodynamic support or too high for nighttime...

Johnson, S.E., 1970: Patents relating to mechanization of timber harvesting. Patent descriptions of timber-harvesting machines from the major wood-producing countries of the world have been collected and classified according to the disclosures made in each. The purpose of the study (which is presented in loose-leaf form in...

Weiner, H.L.; Hafler, D.A., 1998: Treatment of multiple sclerosis by oral administration of bovine myelin. Official Gazette of the United States Patent & Trademark Office Patents 1217(3): 2470, Dec 15

Mcdermott, N.J.; Gandelman, R.; Reinisch, J.M., 1978: Contiguity to male fetuses influences ano genital distance and time of vaginal opening in mice. Female mice located in utero adjacent to 2 male fetuses had longer ano-genital distances and exhibited vaginal opening later than did females proximate to no male fetuses. Females adjacent to 1 male fetus were intermediate on both measures. [Expos...

Stiles, B.M.; Reece, T.Brett.; Hedrick, T.L.; Garwood, R.A.; Hughes, M.G.; Dubose, J.J.; Adams, R.B.; Schirmer, B.D.; Sanfey, H.A.; Sawyer, R.G., 2006: General surgery morning report: a competency-based conference that enhances patient care and resident education. After adopting a night float system, the residency program at the University of Virginia Health System Department of Surgery initiated a daily morning report (MR). The conference was originated to sign out new admissions and consults from the prev...

Derr R.F.; Derr M.I., 1986: Separation of the tremorous and muscular rigidity components of the ethanol withdrawal syndrome in the rat. The alcohol withdrawal syndrome consists of a kinetic tremor, the tremorous component, and a peculiar abnomality of tone called asterixis, the muscular rigidity component. The severity of the ethanol withdrawal syndrome in the rat is generally ass...

Błażej, Pł.; Miasojedow, Błażej.; Grabińska, Młgorzata.; Mackiewicz, Pł., 2016: Optimization of Mutation Pressure in Relation to Properties of Protein-Coding Sequences in Bacterial Genomes. Most mutations are deleterious and require energetically costly repairs. Therefore, it seems that any minimization of mutation rate is beneficial. On the other hand, mutations generate genetic diversity indispensable for evolution and adaptation o...

Urheim, S.; Rabben, S.Inge.; Skulstad, H.; Lyseggen, E.; Ihlen, H.; Smiseth, O.A., 2005: Regional myocardial work by strain Doppler echocardiography and LV pressure: a new method for quantifying myocardial function. There is a need for better methods to quantify regional myocardial function. In the present study, we investigated the feasibility of quantifying regional function in terms of a segmental myocardial work index as derived from strain Doppler echoca...

Giordano, S.; di Renzo, M.F.; Olivero, M.; Mondino, A.; Zhen, Z.; Medico, E.; Comoglio, P.M., 1992: The c-met/HGF receptor in human tumours. European Journal of Cancer Prevention 1 Suppl 3: 45-49

Smith, J.; Wallis, M., 1979: Nursing care study: apple peel syndrome. Crisis: premature birth; an intensive five months. Nursing Mirror 149(8): 36-40