geoscience.net logo
+ Resolve Article
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter

+ Translate
+ Subscribe to Site Feed
GeoScience Most Shared ContentMost Shared Content

B-mode ultrasound measurement of carotid bifurcation stenoses: is it reliable?


, : B-mode ultrasound measurement of carotid bifurcation stenoses: is it reliable?. Vascular and Endovascular Surgery 36(2): 123-135

In the majority of cases, duplex ultrasonography (DU) is the sole imaging study necessary before carotid interventions. Duplex-derived internal carotid artery (ICA) peak systolic velocity (PSV), ICA end-diastolic velocity (EDV) and ICA/common carotid artery (CCA) PSV ratio are the most commonly utilized parameters for predicting critical carotid stenoses. However, the role of direct B-mode image measurement of maximal ICA narrowing is ill defined. The images and records of 192 patients who underwent both arteriography and duplex ultrasonography (DU) of 375 carotid arteries from January 1995 to November 2000 were reviewed. All DUs were performed by registered vascular technologists (n=6). Maximum arteriographic stenosis was determined according to the NASCET study design. With arteriography as the "gold standard," B-mode image (BMI) measurement of the maximal ICA luminal narrowing relative to the carotid bulb (n=162)as well as the peak systolic velocity in the internal carotid artery (PSVICA) (n=330), end-diastolic velocity in the internal carotid artery (EDV(ICA)) (n=198), and the ratio of the PSVs in both the ICA and the CCA (PSVICA/CCA) ratio (n=319) were subjected to receiver operator characteristics (ROC) curves for 3 clinically relevant stenoses thresholds: 50-99%, 60-99%, and 70-99%. A strong correlation was found between B-mode image (BMI)and the NASCET arteriographic measures of carotid stenosis (r =0.80;p<0.001) and was similar among the 6 technologists (r =0.74-0.89;p>0.2). The overall accuracy of BMI measurement to diagnose 50%, 60%,and 70% arteriographic carotid stenosis was 85.3%, 82.2%, and 87%, respectively. BMI measurement was similar to the most accurate PSV(ICA), EDV(ICA), and PSV(ICA/CCA) ratio at all 3 threshold stenoses levels (p>0.3). When combined with the velocity criteria, BMI measurement improved the positive predictive value (PPV) for all arteriographic stenoses thresholds by an average of 12.6% for PSV(ICA), 21.2% for EDV(ICA), and 14.2% for PSV(ICA/CCA) ratio. BMI measurement of carotid bifurcation narrowing is as reliable as duplex-derived velocity criteria in evaluating clinically relevant threshold ICA stenoses. The routine use of B-mode ultrasound in conjunction with the velocity parameters enhances the PPV of carotid DU. Our experience suggests that with current refinements in B-mode resolution, BMI stenosis measurements are accurate among experienced technologists and are a useful adjunct to duplex-derived velocity parameters.

US$29.90

PMID: 11951099


Other references

Ishizuka, S.; Inafune, A.; Hira, T.; Izumi, H.; Ozawa, K.; Takase, M.; Hara, H., 2009: Administration of anti-glucagon-like peptide-2 serum suppresses epithelial cell proliferation of the distal small intestine in weanling rats. We investigated the effects of endogenous glucagon-like peptide-2 (GLP-2) on the development of intestinal mucosa in weanling rats. Three-week-old male weanling Sprague-Dawley rats were administered either anti-GLP-2 or normal rabbit serum every o...

Yarnell, R.; Biehl, D.R.; Tweed, W.A.; Gregory, G.A.; Sitar, D., 1983: The effect of halothane anaesthesia on the asphyxiated foetal lamb in utero. In a previous study, we examined the effects of halothane on the normal foetal lamb in utero. The most significant finding was a 33 per cent fall in foetal mean arterial blood pressure (MABP). Cardiac output and placental blood flow were not affec...

Vetsch, G.; Uehlinger, D.E.; Zuercher-Zenklusen, R.M., 2002: DNR orders at a tertiary care hospital--are they appropriate?. There are no established recommendations in Switzerland on when, how and for what patients DNR orders should be written. Moreover, little is known about current attitudes, patients' preferences, patients' involvement in decision-making a...

Huang, J.S.; Tsai, C.C.; Chou, H.H.; Ting, W.H., 2005: Simulation modeling for nitrogen removal and experimental estimation of mass fractions of microbial groups in single-sludge system. Nitrification-denitrification in a single-sludge nitrogen removal system (SSNRS; with a sufficient carbon source for denitrification) was performed. With an increase in the mixed liquor recycle ratio (R<sub>m</sub>) from 1 to 2, the to...

Messinger, M.; Albert, F.; Rohde, N., 2015: Clinical evaluation of the troponin I assay on radiometer AQT90 FLEX and Beckman Coulter UniCel DxI 800 analyzers. High sensitive troponin assay methods used in emergency departments and those used in hospital laboratories are needed with low imprecision of the analytical method aligned along the cut-off. Presented is a method for adjusting the Troponin I (TnI...

Yamamoto, T.; Matsumoto, J.; Kosaihira, T.; Nomoto, M.; Kitajima, S-ichi.; Arima, T., 2003: A case of gastric fundic polyps during long-term treatment of reflux esophagitis with omeprazole. Nihon Shokakibyo Gakkai Zasshi 100(4): 421-425

Blank, V.C.; Sterin Prync, A.; Retegui, L., 1999: Identification of a linear epitope of interferon-a2b recognized by neutralizing monoclonal antibodies. European Journal of Biochemistry 265(1):

Grant, R.P., 1959: Cardiac hypertrophy; some reflections. Arizona Medicine 16(4): 269-273

Jayamurugan, G.; Umesh, C.P.; Jayaraman, N., 2007: Inherent photoluminescence properties of poly(propyl ether imine) dendrimers. Hydroxyl group terminated poly(propyl ether imine) dendrimers of 1 to 5 generations absorb in the region of 260-340 nm, in MeOH and aqueous solutions. Excitation of a solution of the dendrimers at 330 nm led to an emission at approximately 390 nm....

Mazzei, E.S., 1951: Clinical study of pulmonary abscess. Prensa Medica Argentina 38(17): 1015-1025