Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation


, : Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation. Clinical and Investigative Medicine. Medecine Clinique et Experimentale 33(1): E54-E62

To compare blood pressure readings obtained with two commonly used oscillometric monitors: Omron HEM 711 AC (OM) and Welch-Allyn 52000 series NIBP/oximeter (WA) with mercury sphygmomanometers (Merc) in subjects with atrial fibrillation. We recruited 51 hemodynamically stable subjects with atrial fibrillation. Fifty four subjects in normal sinus rhythm served as controls. Supine blood pressure readings in each arm were recorded simultaneously using one monitor and Merc. The second monitor then replaced the first and readings were repeated. Merc was then switched to the opposite arm, and both monitors retested. Apical heart rates were ascertained with a stethoscope. We used the averaged, same arm Merc readings as "gold standard". Automated blood pressure readings were obtained in all control subjects and in all but three of those with atrial fibrillation. Both monitors, and operators, noted a difference between apical and radial/brachial pulse rates: apical-recorded: Merc 6.1 + or - 15.0; OM 5.5 + or - 13.7; WA 10.0 + or - 21.2 beats per minute. Both monitors were accurate in controls: over 90% of readings were within 10 mmHg of averaged Merc, and both achieved European Hypertension Society standards. In subjects with atrial fibrillation, about one quarter of all oscillometric readings differed from Merc by more than 10 mmHg. Both falsely high and falsely low readings occurred, some up to 30 mmHg. There was no relation between accuracy and heart rate. Single blood pressure readings, taken with oscillometric monitors in subjects with atrial fibrillation differ, often markedly, from those taken manually. Health care professionals should record multiple readings manually, using validated instruments when making therapeutic decisions.

US$29.90

PMID: 20144271


Other references

Gerrits, N.M.; Voogd, J.; Magras, I.N., 1985: Vestibular afferents of the inferior olive and the vestibulo-olivo-cerebellar climbing fiber pathway to the flocculus in the cat. The projection of the vestibular nuclei to the inferior olive was investigated by means of anterograde transport of tritiated leucine. Following injections in the medial and descending vestibular nuclei, terminal labeling was found ipsilaterally i...

Toftemark, G., 1953: Review of medical preparedness. Meddelelser Fra Sundhedsstyrelsen. Denmark. Sundhedsstyrelsen. Beredskabsafdelingen 24: 153-156

Elsharawy, M.; Elzayat, E., 2002: Early results of thrombolysis vs anticoagulation in iliofemoral venous thrombosis. A randomised clinical trial. catheter directed thrombolysis has been advocated for complete and rapid dissolution of iliofemoral deep venous thrombosis (DVT). The aim of our study is to compare, in a randomised trial, local thrombolysis and anticoagulation with anticoagulatio...

Karner J.M.; Sutton S.R.; Papike J.J.; Shearer C.K.; Newville M., 2003: Oxidation state of vanadium in glass and olivine from terrestrial and Martian basalts; implications for oxygen fugacity estimates. Preliminary results using XANES to determine the oxidation state of V, and thus oxygen fugacity of planetary basalts.

Marcus, Y., 2014: The molar volumes of ions in solution, part 7. Electrostriction and hydration numbers of aqueous polyatomic anions at 25 °C. The standard partial molar volumes of 16 polyatomic more-or-less globular anions in aqueous solutions at 25 °C were calculated as the sum of the intrinsic and (negative) electrostrictive volumes and compared with the experimental values. The intr...

Morris, H.M., 1933: Carpocapsa: Demonstrations of Methods of Control. The treatment of two orchards in Cyprus during 1933 with one application of lead arsenate and two of lead arsenate and a proprietary white oil emulsion considerably reduced the proportion of apples attacked by Cydia (Carpocapsa) . Bands of corruga...

Hartwig, E.E.; Buehring, N.; Young, L.D., 1982: Effect of the soybean cyst nematode upon soybean production under different management systems. In field experiments in Mississippi, USA, growing the soybean cyst nematode race 3-resistant variety Centennial continuously for 6 years did not result in a significant increase in Heterodera glycines populations. Yields were not significantly inc...

García-López, P.; Pérez-Urizar, J.; Ibarra, A.; Grijalva, I.; Madrazo, I.; Flores-Murrieta, F.; Castañeda-Hernández, G.; Guízar-Sahagún, G., 1996: Comparison between Sprague-Dawley and Wistar rats as an experimental model of pharmacokinetic alterations induced by spinal cord injury. Two strains of rats, Sprague-Dawley and Wistar, were assayed in order to determine which strain is the more suitable experimental model for the study of pharmacokinetic alterations induced by spinal cord injury. Animals were submitted to spinal co...

Bowick, M.; Nelson, D.R.; Travesset, A., 2004: Curvature-induced defect unbinding in toroidal geometries. Toroidal templates such as vesicles with hexatic bond orientational order are discussed. The total energy including disclination charges is explicitly computed for hexatic order embedded in a toroidal geometry. Related results apply for tilt or ne...

Fenner T., 1995: Ground penetrating radar for identification of mine tunnels and abandoned mine stopes. Mining Engineering 47(3): 280-284