geoscience.net logo
+ Resolve Article
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter

+ Translate
+ Subscribe to Site Feed
GeoScience Most Shared ContentMost Shared Content

Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study


, : Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study. Journal of Heart Valve Disease 23(5): 633-641

Aortic valve replacement (AVR) in patients with a small aortic root is often associated with some degree of obstruction and residual gradients. Stentless valves display better hemodynamic performance than stented valves, and might be ideal in patients with a small aortic annulus. A new stented bioprosthesis, the Trifecta valve, has recently become available and has yielded interesting early results. The study aim was to compare the hemodynamic performance of the Trifecta valve with that of the Freestyle valve in patients with an aortic annulus ≤ 2.3 cm. Between September 2011 and September 2013, a total of 40 patients with pure aortic stenosis and native aortic annulus diameter ≤ 2.3 cm was randomized to receive either a St. Jude Medical Trifecta stented prosthesis (n = 20) or a Medtronic Freestyle stentless prosthesis (n = 20). Hemodynamics results were compared between the two groups on discharge from hospital. The Trifecta valve showed slightly better hemodynamics, with peak gradients of 11 ± 5 mmHg and 17 ± 9 mmHg (p = 0.009), and mean gradients of 5.5 ± 3 mmHg and 7.5 ± 4 mmHg (p = 0.06) for the Trifecta and Freestyle valves, respectively. The average indexed effective orifice area (EOAi) was 1.14 ± 0.23 cm2/m2 and 1.09 ± 0.20 cm2/m2 (p = 0.520) for the Trifecta and Freestyle, respectively. Patient-prosthesis mismatch (PPM) occurred in two patients of the Freestyle group, and in three patients of the Trifecta group. In the present study, the stentless and stented prostheses each yielded comparable and excellent early hemodynamics results. The data obtained suggest that Trifecta valve implantation is a valid means of avoiding PPM after AVR in patients with a small native aortic annulus.

US$29.90

PMID: 25799714


Other references

Kondo, M.; Yamamoto, H.; Ikeda, M.; Horiguchi, M.; Utsunomiya, Y.; Hosoya, T., 2004: Hyperammoniemia due to portal-systemic shunt developed after initiation of hemodialysis in a chronic renal failure patient. Nihon Naika Gakkai Zasshi. Journal of the Japanese Society of Internal Medicine 93(8): 1637-1638

Kojima, M.; Koide, T.; Odani, S.; Ono, T., 1986: Amino acid sequence of the variable region of heavy chain in immunoglobulin (Mot) having unusual papain cleavage sites. An IgGl(lambda) Mot myeloma protein showed a unique susceptibility toward papain digestion. The Fab fragment of Mot was more digestible with papain than the Fc fragment. This phenomenon was found to occur by unusual cleavage of the Fd fragment wit...

Scott, G.; Akhtar, M.L.ntz, M.; Kirk, T.; Swaney, R., 1998: New technology for papermaking: commercializing biopulping. Tappi journal 81(11): 220-225

Gruberg, E.R.; Stirling, R.V., 1974: An autoradiographic study of changes in the frog tectum after cutting the optic nerve. Brain Research 76(2): 359-362

Kilyn I.V.; Shcherba A.S.; Shcherba V.M.; Krupskiy Y.Z., 1990: Geology and petroleum potential of nappe-overthrust structures in the Carpathian region. Post-sedimentation transformations of the Albian-Senonian paleoshelf deposits which contain a great amount of biogenic material are studied. Paleo gas hydrate layers, related to the upper part of the rock base of the ancient continental side, serv...

Venzl, G., 1976: Statistical fluctuations of activity in localized neural populations. A model for the activity of localized neural populations consisting of coupled excitatory and inhibitory subpopulations was generalized to include the effects of statistical fluctuations. By adding Gaussian .DELTA.-correlated noise to the determin...

Seago, B.L., 2001: Establishing a Medical Informatics Curriculum Committee in the school of medicine. Medical Reference Services Quarterly 19(2): 91-94

Anonymous, 2005: Improving cash flow with better charge capture and denial management. Healthcare Financial Management 59(10): 8 P Following Page 112-8 P Following Page 112

Pearce, J.M.; Nicholas, D.J.; Dickinson, A., 1981: The potentiation effect during serial conditioning. Quarterly Journal of Experimental Psychology. B, Comparative and Physiological Psychology 33(Pt 3): 159-179

Likhachev, G.N., 1961: Breeding biology of the Steppe-Buzzard in the sanctuary forest Tulskie zaseki. Trudy Prioksko-Terrasnogo Zapov Moscow, 4: 147-225