geoscience.net logo
+ Resolve Article
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter

+ Translate
+ Subscribe to Site Feed
GeoScience Most Shared ContentMost Shared Content

Real-time contrast ultrasound muscle perfusion imaging with intermediate-power imaging coupled with acoustically durable microbubbles


, : Real-time contrast ultrasound muscle perfusion imaging with intermediate-power imaging coupled with acoustically durable microbubbles. Journal of the American Society of Echocardiography 28(6): 718-26.E2

There is growing interest in limb contrast-enhanced ultrasound (CEU) perfusion imaging for the evaluation of peripheral artery disease. Because of low resting microvascular blood flow in skeletal muscle, signal enhancement during limb CEU is prohibitively low for real-time imaging. The aim of this study was to test the hypothesis that this obstacle can be overcome by intermediate- rather than low-power CEU when performed with an acoustically resilient microbubble agent. Viscoelastic properties of Definity and Sonazoid were assessed by measuring bulk modulus during incremental increases in ambient pressure to 200 mm Hg. Comparison of in vivo microbubble destruction and signal enhancement at a mechanical index (MI) of 0.1 to 0.4 was performed by sequential reduction in pulsing interval from 10 to 0.05 sec during limb CEU at 7 MHz in mice and 1.8 MHz in dogs. Destruction was also assessed by broadband signal generation during passive cavitation detection. Real-time CEU perfusion imaging with destruction-replenishment was then performed at 1.8 MHz in dogs using an MI of 0.1, 0.2, or 0.3. Sonazoid had a higher bulk modulus than Definity (66 ± 12 vs 29 ± 2 kPa, P = .02) and exhibited less inertial cavitation (destruction) at MIs ≥ 0.2. On in vivo CEU, maximal signal intensity increased incrementally with MI for both agents and was equivalent between agents except at an MI of 0.1 (60% and 85% lower for Sonazoid at 7 and 1.8 MHz, respectively, P < .05). However, on progressive shortening of the pulsing interval, Definity was nearly completely destroyed at MIs ≥ 0.2 at 1.8 and 7 MHz, whereas Sonazoid was destroyed only at 1.8 MHz at MIs ≥ 0.3. As a result, real-time CEU perfusion imaging demonstrated approximately fourfold greater enhancement for Sonazoid at an MI of 0.3 to 0.4. Robust signal enhancement during real-time CEU perfusion imaging of the limb is possible when using intermediate-power imaging coupled with a durable microbubble contrast agent.

US$19.90

PMID: 25769666

DOI: 10.1016/j.echo.2015.02.002


Other references

Parrillo J.E., 1986: Endotoxemia is associated with many clinical manifestations of septic shock in humans. Clinical Research: 410a

Mishra R.N., 1976: Structures and tectonics of the Sandur Basin. Miscellaneous Publications, Geological Survey of India 23, Part 2: 457-463

Peryt D., 1988: Middle miocene calcareous nannoplankton stratigraphy of the roztocze region southeastern poland. Calcareous nannoplankton of the Middle Miocene of the Roztocze region has been studied, with light and electron scanning microscopes. Common species belonging to Coccolithus and Reticulofenestra predominate in the investigated material; species be...

Rotenberg, D.; Wells, A.-Jimenez; Chapman, E., J.; Whitfield, A., E.; Goodman, R., M.; Cooperband, L., R., 2007: Soil properties associated with organic matter-mediated suppression of bean root rot in field soil amended with fresh and composted paper mill residuals. The ability of an organic amendment to suppress soil-borne disease is mediated by the complex interactions between biotic and abiotic soil factors. Various microbiological and physicochemical soil properties were measured in field soils with histo...

Gapeeva, MV.; Tselmovich, OL., 1989: On distribution of heavy metals in bottom sediment of the Kuibyshev and Rybinsk Reservoirs. Vodnye Resursy, 1: 170-172

Hochuli, E.; Stoeckli, A.; Kaufmann, P., 1961: Toxaemia of pregnancy. Results of follow-up studies of patients with severe pre-eclampsia. Journal of Obstetrics and Gynaecology of the British Empire 68: 952-960

Kollias N.; Baqer A., 1986: On the assessment of melanin in human skin in vivo. A method for estimating the amount of pigment in normal human skin in vivo is presented. This method is based on remittance spectroscopy. The spectrum of normal skin is compared to amelanotic skin and the logarithm of the ratio is fitted with a st...

Gurden, D., 2016: Clear communication. In health care, effective communication can directly affect positive outcomes. Ineffective or poor communication can cost lives, be it by a missed diagnosis, a medication error or treatment delay.

Stafford C.M., 2006: The spatial response to Severe Tropical Cyclone Larry, March 2006. Pages 116 2006

Gui, L.; Shi, Y-kai.; He, X-hui.; Lei, Y-heng.; Zhang, H-zhi.; Han, X-hong.; Zhou, S-yu.; Liu, P.; Yang, J-liang.; Dong, M.; Zhang, C-gong.; Yang, S.; Qin, Y., 2014: High-dose therapy and autologous stem cell transplantation in peripheral T-cell lymphoma: treatment outcome and prognostic factor analysis. Peripheral T-cell lymphoma (PTCL) carries a poor prognosis with conventional treatment. We retrospectively analyzed data from 45 patients with PTCL who received high-dose therapy and autologous stem cell transplantation (HDT/ASCT) from 1990 to 200...